About DIGITAL ENERGY 3PHASE METER NORMAL (10-40 Amp)
DIGITAL ENERGY 3 PHASE METER NORMAL (1060A)
We are a reliable Manufacturer, Exporter and Supplier of Digital Energy 3 Phase Meter (1060A), designed for accurate energy measurement in industrial and commercial three-phase electrical systems.
This meter is manufactured in compliance with IS 13779:1999 and suitable for 415V, 50 Hz power supply conditions commonly used in India.
The meter ensures stable and precise monitoring of electrical parameters and is ideal for factories, workshops, commercial complexes, and distribution panels.
Key Features
-
Three Phase, Direct Connected (1060A)
-
Voltage Rating: 415V (L-L), 240V (L-N)
-
Frequency: 50 Hz 5%
-
Accuracy Class: Class 1 (kWh)
-
LCD Digital Display with clear parameter indication
-
Measures kWh, kVARh, kVAh, Power Factor
-
Phase-wise Voltage & Current Display
-
Low power consumption
-
Tamper detection and surge protection
-
DIN Rail / Panel Mount (model dependent)
Electrical Performance
-
Operating Voltage Range: 332V 498V
-
Overload Capacity: 1.5 Rated Current
-
Starting Current: 0.004A
-
Frequency Accuracy: 0.1 Hz
Applications in India
-
Industrial manufacturing units
-
Commercial buildings
-
Electrical control panels
-
DG synchronization panels
-
Power distribution monitoring
Build & Safety
-
Flame-retardant, UV-resistant housing
-
IP51 / IP54 protection (as per model)
-
Factory calibrated and tested
-
Reverse phase & phase loss detection
Trade Information
-
Supply Ability: As per order quantity
-
Delivery: Within committed time
-
Packaging: Corrugated box with proper protection
-
Sample: Available on request
-
Domestic Market: All India
- Standard Reference: IS 13779:1999 (or latest version) Static AC Energy Meters.
- Type: Three-Phase, Normal, Multifunction, Static (Electronic) Energy Meter.
- Voltage Rating: 415V 20% (Line to Line) standard for three-phase systems in most countries.
- Current Range: 10A to 60A (direct connection).
- Frequency: 50 Hz 5% (47.5 Hz to 52.5 Hz).
- Metering Functions:
- Active Energy (kWh): Measurement of real power consumption.
- Reactive Energy (kVARh): Measurement of non-working power.
- Apparent Energy (kVAh): Measurement of total power consumption.
- Power Factor (PF): Real-time Power Factor measurement.
- Current (A): Current in each phase.
- Voltage (V): Voltage in each phase (Line to Neutral and Line to Line).
- Frequency (Hz): Frequency of the system.
Electrical Characteristics:
- Voltage Rating:
- 415V (Line to Line).
- 240V (Line to Neutral, for reference in star-connected systems).
- Operating Voltage Range: 80% to 120% of the rated voltage (i.e., 332V to 498V).
- Overload Capacity:
- 1.5 times the rated current (i.e., 90A for a 60A rated meter) for a specified period (typically 1 hour).
- Starting Current: 0.004A (minimum current the meter can measure).
- Rated Current: 10A to 60A (direct connection, no CTs required for currents below 60A).
Accuracy:
- Accuracy Class: Class 1 (1% tolerance for active energy measurement).
- Active Energy (kWh): 1% accuracy at rated load (Class 1).
- Reactive Energy (kVARh): TypicallyClass 2 (2% accuracy).
- Apparent Energy (kVAh): Measured with accuracy in line with Class 2.
- Power Factor: Accuracy typically within 2%.
- Current Measurement: Accuracy typically within 1% over the range of 10A to 60A.
- Voltage Measurement: Accuracy typically within 1% for the line-to-line and line-to-neutral voltage.
- Frequency Measurement: Accuracy within 0.1 Hz.
Display and Metering Functions:
- Display Type: LCD Digital Display with backlight.
- Display Parameters:
- Energy (kWh): Total active energy consumed.
- Reactive Energy (kVARh): Total reactive energy consumed.
- Apparent Energy (kVAh): Total apparent energy consumed.
- Power Factor: Instantaneous power factor.
- Phase Current (A): Current in each of the three phases.
- Phase Voltage (V): Voltage in each phase (L-N and L-L).
- Frequency (Hz): The system frequency.
- Max Demand: If supported, the maximum demand over a period.
- Time-of-Use (TOU): If the meter supports, it can display TOU data based on pre-set tariffs.
- Display Format: Numeric and clear indication of measurements. Typically, the screen will display multiple parameters simultaneously or allow cycling through them.
- Data Retention: Meter retains data even during power failures.
Communication and Remote Monitoring (Optional Features):
- Communication Interface:
- RS-485 (Modbus RTU) for remote reading and integration into SCADA or Building Management Systems (BMS).
- Pulse Output: For external logging devices.
- Data Logging: For recording energy consumption, maximum demand, and fault events (for models supporting data logging).
- Event Logging: Logs important events such as power failures, tampering attempts, etc.
- Time-of-Use (TOU) Support: The meter can support multiple tariff structures depending on the time of the day.
Environmental and Durability Specifications:
- Operating Temperature Range: -10C to +55C (for normal operation).
- Storage Temperature Range: -40C to +70C (storage).
- Humidity: 95% RH max (non-condensing).
- Protection Class: IP51 or IP54 (dust and splashproof).
- Overvoltage Protection: Protection against surges and spikes according to IEC 61000 standards.
Meter Housing and Safety:
- Material: Flame-retardant, UV-resistant plastic housing.
- Mounting:
- Typically DIN Rail Mountable or wall-mounted (depending on the model).
- Installation: Designed for indoor use, but outdoor models may be available with enhanced IP ratings (IP54).
- Tamper Detection:
- Reverse Phase Detection.
- Phase Loss Detection.
- Voltage/Current Surge Protection.
- Short Circuit Protection: Built-in protection against overload and short-circuit conditions.
Compliance and Standards:
- Compliance: The meter adheres to IS 13779:1999 standards for electronic energy meters.
- Verification & Calibration: The meter undergoes factory calibration and verification against national or international standards.
- Certification: The meter typically comes with a verification certificate from authorized agencies, ensuring compliance with IS 13779.
Summary Table of Key Parameters:
| Parameter | Specification |
| Voltage Rating | 415V (Line to Line), 240V (Line to Neutral) |
| Current Range | 10A - 60A |
| Accuracy Class | Class 1 (1% for Active Energy) |
| Frequency | 50 Hz 5% |
| Max Overload | 1.5 x Rated Current (90A for 60A) |
| Starting Current | 0.004A |
| Display | LCD Digital Display |
| Communication | RS-485 (Modbus RTU), Pulse Output (optional) |
| Power Consumption | 0.5W |
| Operating Temperature | -10C to +55C |
| Protection | IP51 (or higher), Tamper-proof features |
| Mounting | DIN Rail or Wall Mountable |
Conclusion:
This Class 1 Three-Phase Energy Meter designed according to IS 13779 is a highly accurate and reliable solution for measuring energy consumption in industrial, commercial, and residential applications. It offers multifunctional metering, supports remote monitoring, and complies with national standards for accuracy and safety.
FAQs of DIGITAL ENERGY 3PHASE METER NORMAL (10-40 Amp):
Q: How is the DIGITAL ENERGY 3PHASE METER NORMAL installed for industrial usage?
A: The meter is installed on appropriate industrial surfaces by connecting it to your three-phase electrical supply, ensuring proper mounting for consistent performance and accurate readings.
Q: What benefits does this meter provide over analog alternatives?
A: It offers digital-only display for clear, precise energy data, 100% accuracy, and reliable performance, which reduces errors and improves overall energy management in industrial settings.
Q: When can I request samples of the DIGITAL ENERGY 3PHASE METER NORMAL?
A: You may request samples as per our sample policy. Simply contact our sales team with your requirements and proposal amount for evaluation and dispatch details.
Q: Where does the company export its digital meters?
A: We export primarily to key markets in Asia, Africa, and the Middle East, familiar for requiring reliable, efficient energy monitoring solutions for industrial applications.
Q: What certifications does the DIGITAL ENERGY 3PHASE METER NORMAL carry?
A: The meter holds relevant certifications complying with industry standards to ensure safety, quality, and reliability for all industrial users.
Q: How does the exchange process work for this product?
A: Exchange requests are managed through a streamlined process, subject to our logistics and sample policy, guaranteeing a smooth and satisfactory transaction for our clients.