About DIGITAL ENERGY SINGLE PHASE METER (MFM) (10-60Amp)
DIGITAL ENERGY SINGLE PHASE MULTIFUNCTION ENERGY METER (1060A)
We are a trusted Manufacturer, Exporter & Supplier of Single Phase Multifunction Energy Meter designed as per IS 13779:1999 for accurate and reliable measurement of electrical parameters in industrial and commercial applications.
This meter is suitable for direct connection and provides precise monitoring of Active, Reactive, and Apparent energy along with real-time electrical parameters.
General Specifications
-
Standard Compliance: IS 13779:1999 (Latest Version)
-
Type: Single Phase Multifunction Electronic Energy Meter
-
Rated Voltage: 230V AC, 50 Hz
-
Frequency Range: 47.5 Hz to 52.5 Hz
-
Current Rating: 1060 Amp (Direct Connected)
-
Metering Parameters:
-
Active Energy (kWh)
-
Reactive Energy (kVARh)
-
Apparent Energy (kVAh)
-
Power Factor
-
Voltage (V)
-
Current (A)
-
Frequency (Hz)
Accuracy Class
-
Active Energy (kWh): Class 1 (1%)
-
Reactive Energy (kVARh): Class 2 (2%)
-
Power Factor: 2%
-
Voltage & Current Measurement: 12%
-
Frequency Accuracy: 0.1 Hz
Electrical Characteristics
Display & Functional Features
Communication & Integration (Optional)
Environmental & Mechanical Specifications
-
Operating Temperature: -10C to +55C
-
Storage Temperature: -40C to +70C
-
Humidity: 95% RH (Non-condensing)
-
Protection Class: IP51 or higher
-
Mounting: Wall Mount / DIN Rail (model dependent)
-
Housing: Flame-retardant, UV-resistant polycarbonate
Safety & Protection
Supply & Packaging Details
-
Packaging: Corrugated box with protective cushioning
-
Supply Ability: As per order quantity
-
Delivery Time: Within committed schedule
-
Export Market: Worldwide
-
Calibration Certificate: Provided
General Specifications:
- Standard Reference: IS 13779: 1999 (latest version) Static AC Energy Meters.
- Type: Single-phase, Multifunction Electronic Energy Meter.
- Voltage Rating: 230V AC, Single-phase, 50 Hz 2% (standard operating voltage).
- Current Range: 10A to 60A (direct connected).
- Frequency Range: 50 Hz 5% (i.e., 47.5 Hz to 52.5 Hz).
- Metering: Active energy (kWh), Reactive energy (kVARh), Apparent energy (kVAh), Power Factor, Current, Voltage, Frequency.
- Accuracy Class: Class 1 or Class 2 (depending on the model) Accuracy tolerance of 1% or 2% for active energy measurement.
2. Electrical Characteristics:
- Voltage: 230V, Single-phase, 50Hz.
- Operating Voltage Range: 160V to 270V (tolerant to fluctuations).
- Overload Capacity:
- Typically, the meter can handle 1.5 times the rated current (e.g., 90A max for 60A rated meters) for a specified period, often 1 hour.
- Starting Current: 0.004A (typically, this is the minimum current the meter can measure, under which it should register energy).
- Rated Current: 10A to 60A (direct connected).
3. Accuracy:
- Active Energy (kWh): Class 1 (1% for consumption measurement under load conditions).
- Reactive Energy (kVARh): TypicallyClass 2 (2% for measurement of reactive energy).
- Power Factor Measurement: Typically within 2% accuracy range.
- Current and Voltage: Accuracy for measuring current and voltage is typically 1-2% within the rated current and voltage range.
- Frequency: Accuracy 0.1 Hz.
4. Display and Functionality:
- Display Type: LCD (Liquid Crystal Display) for easy reading of the values.
- Display Parameters:
- Energy (kWh, kVARh, kVAh)
- Power Factor
- Current (A)
- Voltage (V)
- Frequency (Hz)
- Max Demand (if supported)
- Time-of-Use (TOU) data (if supported).
- Display Readings: Clear digital display of energy consumption, power factor, and other parameters.
- Power Loss: Low power consumption of the meter for continuous operation, typically 0.5W for the meter.
5. Communication & Remote Monitoring (Optional Features):
- Communication Ports: RS-485, Modbus RTU, etc. (for remote reading and integration with Building Management Systems or SCADA).
- Data Logging: Some multifunction meters provide logging for demand, load profiles, and time-of-use data.
- Pulse Output: For external integration or data logging (optional in some models).
6. Environmental and Durability Specifications:
- Operating Temperature Range: -10C to +55C (for normal operation).
- Storage Temperature Range: -40C to +70C.
- Humidity: 95% RH max (non-condensing).
- Protection Class: IP51 (or higher), dust and splashproof, depending on the design.
- Mounting: Wall-mountable, typically with DIN rail mounting available for certain models.
7. Meter Housing and Safety:
- Material: Flame-retardant, UV-resistant plastic housing.
- Tamper Detection: Anti-tamper seals and mechanisms, including reverse-phase detection and over-voltage protection.
- Short Circuit Protection: Built-in protection against overload or short circuit in the event of wiring faults.
- Phase Reversal Detection: Some models feature phase reversal detection for additional security.
8. Compliance and Standards:
- Compliance: IS 13779: 1999 (with updates, if applicable).
- Verification & Calibration: The meters should be subject to factory calibration and verification against national or international standards (e.g., National Standards or Standards of Weights and Measures).
- Certificate: The meter is usually issued with a verification certificate that certifies its calibration and accuracy under standard conditions.
9. Other Features (Optional in Some Models):
- Time-of-Use (TOU) Metering: For varying tariffs based on consumption at different times of the day.
- Event Logging: Logging of fault conditions, power outages, and other significant events.
- Real-time Data: Some multifunction meters support real-time monitoring of power usage, offering valuable insight for energy management.
10. Installation and Operation:
- Connection Type: Direct connection (no need for external current transformers unless exceeding rated current).
- Installation Location: Suitable for indoor or outdoor installation (IP rating permitting).
- Installation Guidelines: Proper mounting per manufacturer's instructions to ensure safety and accurate readings.
Summary of Key Parameters (Example):
| Parameter | Specification |
| Voltage | 230V 20% |
| Current Range | 10A - 60A |
| Accuracy Class | Class 1 for kWh, Class 2 for kVARh |
| Frequency | 50Hz 5% |
| Max Overload | 1.5 x rated current (90A for 60A) |
| Temperature Range | -10C to +55C |
| Humidity | 95% RH max (non-condensing) |
| Display | LCD digital display |
| Communication | RS-485, Modbus (optional) |
| Power Consumption | 0.5W |
Conclusion:
These GTPs ensure the single-phase multifunction energy meter provides accurate energy measurement and meets industry standards for residential and small commercial applications. Always refer to the product's specific technical datasheet for finer details, as manufacturers may include additional features beyond the base standards.
Would you like more detailed insights into how specific features work, such as time-of-use metering or communication protocols?
FAQs of DIGITAL ENERGY SINGLE PHASE METER (MFM) (10-60Amp):
Q: How accurate is the DIGITAL ENERGY SINGLE PHASE METER (MFM) for industrial use?
A: This meter provides 100% accuracy, ensuring precise readings for reliable energy monitoring in demanding industrial environments.
Q: What are the main application areas for this energy meter?
A: The DIGITAL ENERGY SINGLE PHASE METER (MFM) is ideal for factories, industrial zones, and warehouses requiring accurate power measurement and monitoring.
Q: Which materials are used in the construction of this meter?
A: It is constructed from a combination of sturdy metal and high-grade plastic, lending durability and long-lasting performance.
Q: What features set this meter apart from standard models?
A: Its digital-only display, variety of size options, robust build, and exceptional accuracy distinguish it as a top-tier device for energy management.
Q: How is the shipment and packaging handled for this product?
A: Meters are carefully packaged to prevent damage, with timely shipments that ensure products arrive safely and promptly at your location.
Q: What certifications does this digital energy meter hold?
A: The energy meter is certified to meet strict industry standards, ensuring both quality and safety in every unit supplied.