About DIGITAL ENERGY SINGLE PHASE METER (5-30Amp)
General Specifications:
- Standard Reference: IS 13779: 1999 (latest version) Static AC Energy Meters.
- Type: Single-phase, Multifunction Electronic Energy Meter.
- Voltage Rating: 230V AC, Single-phase, 50 Hz 2% (standard operating voltage).
- Current Range: 10A to 60A (direct connected).
- Frequency Range: 50 Hz 5% (i.e., 47.5 Hz to 52.5 Hz).
- Metering: Active energy (kWh), Reactive energy (kVARh), Apparent energy (kVAh), Power Factor, Current, Voltage, Frequency.
- Accuracy Class: Class 1 or Class 2 (depending on the model) Accuracy tolerance of 1% or 2% for active energy measurement.
2. Electrical Characteristics:
- Voltage: 230V, Single-phase, 50Hz.
- Operating Voltage Range: 160V to 270V (tolerant to fluctuations).
- Overload Capacity:
- Typically, the meter can handle 1.5 times the rated current (e.g., 90A max for 60A rated meters) for a specified period, often 1 hour.
- Starting Current: 0.004A (typically, this is the minimum current the meter can measure, under which it should register energy).
- Rated Current: 10A to 60A (direct connected).
3. Accuracy:
- Active Energy (kWh): Class 1 (1% for consumption measurement under load conditions).
- Reactive Energy (kVARh): TypicallyClass 2 (2% for measurement of reactive energy).
- Power Factor Measurement: Typically within 2% accuracy range.
- Current and Voltage: Accuracy for measuring current and voltage is typically 1-2% within the rated current and voltage range.
- Frequency: Accuracy 0.1 Hz.
4. Display and Functionality:
- Display Type: LCD (Liquid Crystal Display) for easy reading of the values.
- Display Parameters:
- Energy (kWh, kVARh, kVAh)
- Power Factor
- Current (A)
- Voltage (V)
- Frequency (Hz)
- Max Demand (if supported)
- Time-of-Use (TOU) data (if supported).
- Display Readings: Clear digital display of energy consumption, power factor, and other parameters.
- Power Loss: Low power consumption of the meter for continuous operation, typically 0.5W for the meter.
5. Communication & Remote Monitoring (Optional Features):
- Communication Ports: RS-485, Modbus RTU, etc. (for remote reading and integration with Building Management Systems or SCADA).
- Data Logging: Some multifunction meters provide logging for demand, load profiles, and time-of-use data.
- Pulse Output: For external integration or data logging (optional in some models).
6. Environmental and Durability Specifications:
- Operating Temperature Range: -10C to +55C (for normal operation).
- Storage Temperature Range: -40C to +70C.
- Humidity: 95% RH max (non-condensing).
- Protection Class: IP51 (or higher), dust and splashproof, depending on the design.
- Mounting: Wall-mountable, typically with DIN rail mounting available for certain models.
7. Meter Housing and Safety:
- Material: Flame-retardant, UV-resistant plastic housing.
- Tamper Detection: Anti-tamper seals and mechanisms, including reverse-phase detection and over-voltage protection.
- Short Circuit Protection: Built-in protection against overload or short circuit in the event of wiring faults.
- Phase Reversal Detection: Some models feature phase reversal detection for additional security.
8. Compliance and Standards:
- Compliance: IS 13779: 1999 (with updates, if applicable).
- Verification & Calibration: The meters should be subject to factory calibration and verification against national or international standards (e.g., National Standards or Standards of Weights and Measures).
- Certificate: The meter is usually issued with a verification certificate that certifies its calibration and accuracy under standard conditions.
9. Other Features (Optional in Some Models):
- Time-of-Use (TOU) Metering: For varying tariffs based on consumption at different times of the day.
- Event Logging: Logging of fault conditions, power outages, and other significant events.
- Real-time Data: Some multifunction meters support real-time monitoring of power usage, offering valuable insight for energy management.
10. Installation and Operation:
- Connection Type: Direct connection (no need for external current transformers unless exceeding rated current).
- Installation Location: Suitable for indoor or outdoor installation (IP rating permitting).
- Installation Guidelines: Proper mounting per manufacturer's instructions to ensure safety and accurate readings.
Summary of Key Parameters (Example):
|
Parameter
|
Specification
|
|
Voltage
|
230V 20%
|
|
Current Range
|
10A - 60A
|
|
Accuracy Class
|
Class 1 for kWh, Class 2 for kVARh
|
|
Frequency
|
50Hz 5%
|
|
Max Overload
|
1.5 x rated current (90A for 60A)
|
|
Temperature Range
|
-10C to +55C
|
|
Humidity
|
95% RH max (non-condensing)
|
|
Display
|
LCD digital display
|
|
Communication
|
RS-485, Modbus (optional)
|
|
Power Consumption
|
0.5W
|
Conclusion:
These GTPs ensure the single-phase multifunction energy meter provides accurate energy measurement and meets industry standards for residential and small commercial applications. Always refer to the product's specific technical datasheet for finer details, as manufacturers may include additional features beyond the base standards.
Would you like more detailed insights into how specific features work, such as time-of-use metering or communication protocols?
Reliable Solution for Diverse ApplicationsThis single-phase meter is specifically engineered for both residential and industrial energy monitoring. It integrates seamlessly into different environments, providing precise measurements while withstanding a broad temperature range. Its IP51 protection ensures longevity and consistent performance in challenging conditions.
Precision and Durability CombinedThanks to its 100% accuracy rate and construction from durable metal and plastic, the Digital Energy Meter delivers consistent results. The meter's 1-year warranty attests to its reliability and the manufacturer's commitment to quality, making it an excellent choice for distributors, exporters, and users in India.
FAQ's of DIGITAL ENERGY SINGLE PHASE METER (5-30Amp):
Q: How is the Digital Energy Single Phase Meter installed?
A: The meter is installed by connecting it to the main electrical supply line. Professional installation is recommended to ensure safe and accurate operation, and it can accommodate various size specifications depending on your setup.
Q: What makes this meter suitable for both residential and industrial use?
A: Its broad operating temperature range, sturdy construction from metal and plastic, and IP51 protection allow the meter to function reliably in diverse environments, whether at home or in industrial facilities.
Q: When should the meter be serviced or checked?
A: Routine checks are advisable annually or as indicated by local regulations. The meter's 1-year warranty ensures manufacturer support within its initial usage period.
Q: Where can this energy meter be used?
A: It is designed for usage across India and is suitable for residential dwellings, industrial premises, and other facilities requiring single-phase energy monitoring.
Q: What process should be followed if the meter malfunctions within the warranty period?
A: In case of malfunction, contact the supplier or manufacturer with warranty documentation. The product is covered by a 1-year warranty, so eligible repairs or replacements will be managed as per warranty terms.
Q: What are the main benefits of using this digital meter?
A: The main advantages are its 100% measurement accuracy, robust build quality, wide operating conditions, and reliability backed by a 1-year warranty. It helps ensure precise energy usage monitoring and reduces the risk of billing errors.
Q: How does the protection system benefit users?
A: Featuring IP51 protection, the meter resists dust and moisture ingress, ensuring longer service life and dependable performance in various environments.